Input
Result
Footprint attribute:
pas2-ipc(density=C, PE=126+-10mil, PT=63+-6mil, PC=20+-10mil)
Download footprint file
|
|
Documentation
pas2-ipc(density=C, PE=126+-10mil, PT=63+-6mil, PC=20+-10mil)
two terminal passives (e.g. 1206) using IPC from component drawing
Generate a two terminal passive footprint with rectangular pads component drawing using IPC-7351 formulas and tables
pas2-ipc parameters
Ordered list (positions): density,PE,PT,PC,PG
name | man dat ory | description | value (bold: default)
|
---|
density
| yes
| board density; C=high density, B=moderate density, A=general (low density)
|
| PE
|
| pin extent (with tolernace)
|
| PT
| yes
| pin thickness (with tolernace); really the width of the lead
|
| PC
| yes
| pin contact length (with tolernace); specify either this or PG
|
| PG
|
| pin gap (with tolernace); specify either this or PC
|
| datasheet
|
| url to the datasheet dimensions are coming from
|
| F
| yes
| fab tolerance in +-mm
|
| P
| yes
| part placement tolerance in +-mm
|
| silk_thickness
| yes
| thickness of silk graphic lines; diametr of pin 1 dot is calculated from this too
|
| mask_offs
| yes
| gap between copper pad edge and mask cutout edge
|
| glue_thick
| yes
| default line thickness for glue on adhesive layers; if 0 omit the layer
|
| glue_dots
| yes
| print dots instead of lines for glue when non-zero
|
| pad_rounding
|
| rectangular pad corner rounding radius (0 for sharp corners)
|
Dimension: a number with an optional unit (mm or mil, default is mil)
|
|