Input
Result
Footprint attribute:
qfp-ipc(density=B, NL=30, NW=20, BL=19.9~20.1, BW=13.9~14.1, PP=0.65, PEL=23.0~23.4, PEW=17~17.4, PT=0.2~0.4, PC=0.73~1.03)
Download footprint file
|
|
Documentation
qfp-ipc(density=B, NL=30, NW=20, BL=19.9~20.1, BW=13.9~14.1, PP=0.65, PEL=23.0~23.4, PEW=17~17.4, PT=0.2~0.4, PC=0.73~1.03)
square flat pack (qfp) with gullwing leads
Generate a square flat pack footprint from component drawing using IPC-7351 formulas and tables
qfp-ipc parameters
Ordered list (positions): density,N,NL,NW,BS,BL,BW,PE,PEL,PEW,PP,PT,PC,PG,PGL,PGW,ECPL,ECPW
| name | man dat ory | description | value (bold: default)
|
|---|
| density
| yes
| board density; C=high density, B=moderate density, A=general (low density)
|
| | N
|
| number of leads in square case
|
| | NL
|
| number of leads on one side along length (vertical) in rectangular case
|
| | NW
|
| number of leads on one side along width (horizontal) in rectangular case
|
| | BS
|
| plastic body size (with tolernace); in case of square body
|
| | BL
|
| plastic body length (vertical; with tolernace); in case of rectangular body
|
| | BW
|
| plastic body width (horizontal; with tolernace); in case of rectangular body
|
| | PP
| yes
| nominal pitch (computed assuming no missing leads, so 6 or 8 leads)
|
Dimension: a number with an optional unit (mm or mil, default is mil)
| | PE
|
| pin extent (with tolernace) in case of square body
|
| | PEL
|
| pin extent (with tolernace) along body length (vertical) in case of square body
|
| | PEW
|
| pin extent (with tolernace) along body width (horizontal) in case of square body
|
| | PT
| yes
| pin thickness (with tolernace); really the width of the lead
|
| | PC
|
| pin contact length (with tolernace); specify either this or PGL; square case
|
| | PGL
|
| pin gap (with tolernace) along the length of the body (vertical); specify either this or PC; rectangular case
|
| | PGW
|
| pin gap (with tolernace) along the length of the body; specify either this or PC; rectangular case
|
| | ECPL
| yes
| exposed center pad length (same direction as BL); 0 or empty if no exposed center pad
|
| | ECPW
| yes
| exposed center pad width (same direction as BW); 0 or empty if no exposed center pad
|
| | datasheet
|
| url to the datasheet dimensions are coming from
|
| | CPVP
| yes
| center pad via grid pitch (distance between vias); 0 or empty for no vias
|
Dimension: a number with an optional unit (mm or mil, default is mil)
| | CPVHD
| yes
| center pad via hole diameter
|
Dimension: a number with an optional unit (mm or mil, default is mil)
| | CPVCD
| yes
| center pad via copper diameter
|
Dimension: a number with an optional unit (mm or mil, default is mil)
| | CPPAT
| yes
| center pad pattern type
|
|
none
| no pattern, round corner rectangle slightly smaller than the pad
| |
chamfer
| small segments with chamfer corners that avoid vias
| |
nopaste
| no paste at all
|
| | CPPG
| yes
| center pad pattern gap; nominal distance between pattern elements
|
Dimension: a number with an optional unit (mm or mil, default is mil)
| | F
| yes
| fab tolerance in +-mm
|
| | P
| yes
| part placement tolerance in +-mm
|
| | silk_thickness
| yes
| thickness of silk graphic lines; diametr of pin 1 dot is calculated from this too
|
| | mask_offs
| yes
| gap between copper pad edge and mask cutout edge
|
| | glue_thick
| yes
| default line thickness for glue on adhesive layers; if 0 omit the layer
|
| | glue_dots
| yes
| print dots instead of lines for glue when non-zero
|
| | pad_rounding
|
| rectangular pad corner rounding radius (0 for sharp corners)
|
Dimension: a number with an optional unit (mm or mil, default is mil)
|
|