Input
Result
Footprint attribute:
sot23-rfp(N=3, PW=0.6, PL=0.7, PRP=2, PP=0.95, BL=2.8~3.0, BW=1.2~1.4)
Download footprint file
|
|
Documentation
sot23-rfp(N=3, PW=0.6, PL=0.7, PRP=2, PP=0.95, BL=2.8~3.0, BW=1.2~1.4)
sot23 using recommended footprint drawing
Generate a sot23 footprint mainly from recommended footprint (copper pad) drawing, optionally also using component drawing for silk, assembly and courtyard layers
sot23-rfp parameters
Ordered list (positions): N,PW,PL,PRP,PP,BL,BW,PP,PE,PT,PC,PG,CYE
name | man dat ory | description | value (bold: default)
|
---|
N
| yes
| number of leads
|
| PW
| yes
| pad width
|
Dimension: a number with an optional unit (mm or mil, default is mil)
| PL
| yes
| pad length
|
Dimension: a number with an optional unit (mm or mil, default is mil)
| PRP
| yes
| pad row pitch: distance between center of pads of the two rows
|
Dimension: a number with an optional unit (mm or mil, default is mil)
| PP
| yes
| nominal pitch (computed assuming no missing leads, so 6 or 8 leads)
|
Dimension: a number with an optional unit (mm or mil, default is mil)
Default: 0.95
| BL
|
| plastic body length (with tolernace)
|
| BW
|
| plastic body width (with tolernace)
|
| PE
|
| pin extent (with tolernace)
|
| PT
|
| pin thickness (with tolernace); really the width of the lead
|
| PC
|
| pin contact length (with tolernace); specify either this or PG
|
| PG
|
| pin gap (with tolernace); specify either this or PC
|
| datasheet
|
| url to the datasheet dimensions are coming from
|
| F
| yes
| fab tolerance in +-mm
|
| P
| yes
| part placement tolerance in +-mm
|
| silk_thickness
| yes
| thickness of silk graphic lines; diametr of pin 1 dot is calculated from this too
|
| mask_offs
| yes
| gap between copper pad edge and mask cutout edge
|
| glue_thick
| yes
| default line thickness for glue on adhesive layers; if 0 omit the layer
|
| glue_dots
| yes
| print dots instead of lines for glue when non-zero
|
| pad_rounding
|
| rectangular pad corner rounding radius (0 for sharp corners)
|
Dimension: a number with an optional unit (mm or mil, default is mil)
|
|